 Embedded Power for Business-Critical Continuity
BXB150 Series
Single output
Total Power: 150 W Input Voltage: 18 - 36 Vdc 36 - 75 Vdc # of Outputs: Single
Rev.05.13.08 bxb150 1 of 4
Electrical Specifications
Output
Special Features
* Industry standard footprint MTBF >1.4 million hours (Bellcore 332) * Input voltage to ETS300-132-2 * Adjustable output voltage * No minimum load required * Separate case ground pin * 2:1 input range for battery powered applications * Undervoltage lockout (UVLO) * UL, VDE and CSA safety approvals * Available RoHS compliant * 2 year warranty
Voltage adjustability: Setpoint accuracy: Line regulation Load regulation Minimum load Overshoot Undershoot Ripple and noise 5 Hz - 20 MHz (see note 1) Temperature coefficient Transient response (see note 2) Remote sense
Low line to high line Full load to min. load At turn on and turn-off 3.3 V and 5 V 12V and 15 V
60% to 110% 1.0% 0.5% 0.10% 0% None None 75 mV pk-pk, 20 mV rms 100 mV pk-pk, 30 mV rms 0.01% / C 2.0% max. deviation 170 srecovery to within 1.0% 0.5 Vdc transmission line drop compensation
Safety
VDE0805/EN60950/IEC950 UL1950 CSA C22.2 No. 950
Embedded Power for Business-Critical Continuity
Input
Input voltage range Input current Input current (max.) (See note 4) Input reflected ripple Active low remote ON/OFF Logic compatiblity ON OFF Undervoltage lockout: 24 Vin nominal 48 Vin nominal No load Remote OFF 24 Vin 48 Vin (See note 6) (See note 7) Open collector ref to -input 1.2 Vdc max. Open circuit 24 Vin: power-up 24 Vin: power-down 48 Vin: power-up 48 Vin: power-down Power-up Remote ON/OFF 17 V 16.3 V 34 V 32.5 V 20 ms 20 ms Level A Level A Level A See table 1500 Vdc 1500 Vdc 1500 Vdc 500 kHz typ. VDE0805, EN60950, IEC950 UL1950, CSa c22.2 No. 950 18 - 36 Vdc 36 - 75 Vdc 130 mA max. 20 mA max. 9.0 A max. @ lo max. and Vin = 0 to 75 V 6.5 A max. @ lo max. and Vin = 0 to 75 V 5 mA pk-pk
Rev.05.13.08 bxb150 2 of 4
Startup time (see note 8)
EMC Charateristics
Conducted emissions (see note 3) Bellcore 1089 FCC part 15 EN55022, CISPR22
General Specifications
Efficiency Isolation voltage Input/case Input/output Output/case Fixed
Switching frequency Approvals and standards (see note 5) Case material Weight MTBF
Aluminum baseplate with plastic case 110 g (3.88 oz) Bellcore 332 1,400,000 hours MIL-HDBK-217F 580,000 hours min. @ 40 C, 100% FL
Environmental Specifications
Thermal performance Altitude Vibration Protection Short-circuit Overvoltage Undervoltage Thermal Operating case temp. Non-operating Operating Non-operating 5 - 500 Hz -40 C to +100 C -55 C to +125 C 10,000 feet max. 40,000 feet max. 2.4 G rms (approx.) Continuous, automatic recovery Non-latching Non-latching 110 C baseplate, automataic recovery Telecom Specifications Central office interface A ETS300-132-2
Embedded Power for Business-Critical Continuity
Ordering Information
Output Power (Max.) Input Voltage OVP Output Voltage Output Current (Min.) Output Current (Max.) Efficiency (Typ.) Regulation Line Load Model Number
Rev.05.13.08 bxb150 3 of 4
100 W 100 W 150 W 150 W 150 W Notes
18 - 36 Vdc 36 - 75 Vdc 36 - 75 Vdc 36 - 75 Vdc 36 - 75 Vdc
4.3 Vdc 4.3 Vdc 6.5 Vdc 14.5 Vdc 17.5 Vdc
3.3 V 3.3 V 5V 12 V 15 V
0A 0A 0A 0A 0A
30 A 30 A 30 A 12.5 A 10 A
77% 79% 84% 84% 88%
0.05% 0.05% 0.05% 0.05% 0.05%
0.1% 0.1% 0.1% 0.1% 0.1%
BXB150-24S3V3FLTJ BXB150-48S3V3FLTJ BXB150-48S05FLTJ BXB150-48S12FLTJ BXB150-48S15FLTJ
Measured with 10 F tantalum capacitor and 1 F ceramic capacitor across output. 2 di/dt = 0.1 A/1 s, Vin = 48 Vdc, Tc = 25 C, load change = 0.5 lo max. to 0.75 lo max. and 0.75 lo max. to 0.5 lo max. 3 Units should be characterised within systems. External components required. 4 Input fusing is recommended based on surge current and maximum input current. 5 This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. 6 Simulated source impedance of 12 H. 12 H inductor in series with +Vin. 7 Active high remote ON/OFF option is available (standard product is active low), designate with the suffix `FHT' e.g. BXB150-48S05FHTJ. Consult factory for further details and options. 8 Start-up into resistive load. 9 The `J' suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special request, please contact your local sales representative for details. 10 NOTICE: Some models do not support all options. Please contact your local sales representative or use the on-line model number search tool at http://www.powerconversion.com to find a suitable alternative.
1
External Output Trimming Output can be externally trimmed by using the method shown.
8
Pin connections
Pin Number Function
TRIM UP 7 RT1 OR RT2 TRIM DOWN 6
1 2 3 4 5 6 7 8 9
+Vin Remote ON/OFF Case -Vin -Vout -Sense Trim +Sense +Vout
Mechanical Drawing
VIEW SHOWN PIN SIDE UP
1.90 (48.26) 0.500 (12.69) 0.010 (0.25)
+SEN TRIM -SEN
0.190 (4.83) 0.010 (0.25)
0.200 (5.08) Min. Length for all Input and Output Pins
1.000 (25.40) 0.400 (10.16) 1.400 (35.56)
CASE
Vo (-)
VI (-)
0.700 (17.77) 0.400 (10.16) 1.000 (25.40)
2.000 (50.80)
2.40 (60.96) Max.
ON/OFF
1.400 (35.56)
7 x O.040 (1.02) 0.002 (0.05) 0.190 (4.83) 0.010 (0.25) 2.28 (57.91) Max. 2 x O.080 (2.03) 0.002 (0.05) 4 x M3 x 0.5 Through 0.500 (12.70)
ALL DIMENSIONS IN INCHES (mm)
Tolerance : x.xx 0.02in. (0.51mm) x.xxx 0.010in. (0.254mm)
Vo(+)
VI(+)
Embedded Power for Business-Critical Continuity
Americas
5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 (760) 930 4600 Facsimile: +1 (760) 930 0698
Rev.05.13.08 bxb150 4 of 4
Europe (UK)
Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355
Asia (HK)
14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888
For global contact, visit:
www.powerconversion.com techsupport.embeddedpower @emerson.com
While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions.
Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection EmersonNetworkPower. com
Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. (c)2008 Emerson Electric Co.


▲Up To Search▲   

 
Price & Availability of BXB150-48S15FLTJ

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X